How to Create a DoIP Connection with a BMW ENET cable

How-to: create a DoIP connection with a BMW ENET cable on Mercedes Benz DTS Monaco engineering software.

Configuration: 

Bus System Interface:D-PDU API
D-PDU API Version: Berner and Mattner Systemtechnik GmbH GDPM_UNIT
Module Type: MVCI_ISO_13400_DOIP
Vendor Module Name: —-
Cable: CABLE_PART_F_ECOM

– Physical links
IEE_802_3: Ethernet 1

 

*This configuration requires DTS Monaco freshly installed and no other BMW VW or vpn Software etc in that pc, straight away it work.

Successfully flashed multiple HU5S1 Head units on w205,w212 W117 etc by dts monaco without a problem. So try at your own risk.

Another configuration works too.

Bus System Interface: D-PDU API
D-PDU API Version: Softing AG EDIC_D_PDU_API_xx_xx_xxx (any version)
Module Type: MVCI_ISO_13400_DOIP_Collection
Vendor Module Name: —-
Cable: Ethernet_Cable

– Physical links
IEE_802_3: Ethernet 1

Note:
For BMW connection IP Address must be set but for Doing working on Mercedes IP address must be automatic.